Contents Banner

Completely new.
Welcome to the versatile SDGR hygrometer

Portable Dewpoint Meter
Dew point readings on flowing dry air or gas
Moisture Log
SSDIRG
Direct Connection of the Moisture Sensor to Computer
  • Fast, one second for 99% response, dry to wet.
  • Indication of ANY moisture from 1 part per billion.
  • User 5 second calibration check. .Economic Price
  • Wet Alarm & Dry Alarm.
  • Sensor included. .20 years sensor life.
  • Large clear digital display with back light.
  • Two years guarantee on meter and sensor .
  • Class 1 Quality Control ISO 9002. .4-20 mA. output.
  • Supplied complete with free table stand

 

The Super Dew

A Versatile, Dry Air Hygrometer with an economy price. 

Ranges:
SDS with Silver spot sensor range -110/-20 c. dew point SDP with purple spot sensor range -100/+20c. dew point. SDR with Red spot sensor range. -80/-20c. dew point SDG -80 / 0 c. dew point

This SHA W user friendly hygrometer, with the new silver spot sensor , has a range of-110 c. to +20 c dew point, a fast, one second time for 99% change from dry to wet. Five second calibration checking, 20 years sensor life, two years no quibble guarantee on hygrometer and sensor, and has user recalibration, not available elsewhere. Users of mirror type hygrometers know that frost point is not dew point, but the Super- Dew can be easily user set to agree with any particular calibration by means of the "DRY" & "WET' controls.

50 years know how, devoted to moisture measurement, since Leonard Shaw's original invention of electronic hygrometers and peltier cooled, mirror type, frost point moisture meters, ensures an incredible accuracy of better than one part moisture in a million parts of very dry air or gas and indication of any moisture from one part per billion.

Shaw sensors have 24 cts, pure gold internal filters and are delivered in a special dry pack to give additional dry down if needed. They are fully user interchangeable. Sensors connected by coaxial cable can do spot checks or give continuous indication in still or flowing dry air or gas. Air dryers can be controlled. They have 1000 times the capacitance of other moisture sensors. Only room air is needed for the unique Shaw Automatic Calibration which can be done in seconds by the user. Shaw unit SU4, reduces dryer pressure to ambient, (the correct way) and supplies air flow to the sensor .

Specifications

Free table stand panel mounting springs or wall mount bracket are provided. Free rotary indicator for water vapour pressure, parts per million moisture, water content in lbs. Dew point in Fahrenheit. Dew point at different pressures. Large digit four figure indicator with back light. Coaxial cable sensor lead. Wet alarm and Dry alarm switches. Dry change over switch with green panel light. Wet change over switch with Red panel light. Output 4-20 m.a. d.c. Panel cut out dimensions, Depth overall 150 m/m Width 135 m/m Height 66m/m Weight 570 grams. (about I lb) Class I quality to ISO 90002. Guaranteed 2 years.

Please order for either 23Ov .or 11 Ov .

WE HAVE BEEN IMPROVING MOISTURE SENSORS FOR 50 YEARS. HOW ABOUT THAT?

 

Price List


AIR & LIQUID SYSTEMS, INC. * 1426 MAGAZINE STREET * NEW ORLEANS, LA 70130
BUS: (504) 523-1789  *  FAX: (504) 522-3611
sales@shawdewpoint.com

© COPYRIGHT AIR LIQUID SYSTEMS, INC. 2004